Kot-Wasik A, Zabiegała B, Urbanowicz M, et al. Advances in passive sampling in environmental studies[J]. Analytica Chimica Acta, 2007, 602(2):141-163
Huckins J N, Manuweera G K, Petty J D, et al. Lipid-containing semipermeable membrane devices for monitoring organic contaminants in water[J]. Environmental Science & Technology, 1993, 27(12):2489-2496
Vrana B, Allan I J, Greenwood R, et al. Passive sampling techniques for monitoring pollutants in water[J]. TrAC Trends in Analytical Chemistry, 2005, 24(10):845-868
Booij K, Vrana B, Huckins J N. Chapter 7 Theory, modelling and calibration of passive samplers used in water monitoring[J]. Comprehensive Analytical Chemistry, 2007, 48:141-169
Alvarez D A, Petty J D, Huckins J N, et al. Development of a passive, in situ, integrative sampler for hydrophilic organic contaminants in aquatic environments[J]. Environmental Toxicology and Chemistry, 2004, 23(7):1640-1648
Booij K. Passive sampler exchange kinetics in large and small water volumes under mixed rate control by sorbent and water boundary layer[J]. Environmental Toxicology and Chemistry, 2021, 40(5):1241-1254
Belles A, Pardon P, Budzinski H. Development of an adapted version of polar organic chemical integrative samplers (POCIS-Nylon)[J]. Analytical and Bioanalytical Chemistry, 2014, 406(4):1099-1110
Park G. The mathematics of diffusion:J. Crank Clarendon Press, Oxford, 1975.2nd edn. 414 pp. £12.50[J]. Polymer, 1975, 16(11):855
Mutzner L, Vermeirssen E L M, Mangold S, et al. Passive samplers to quantify micropollutants in sewer overflows:Accumulation behaviour and field validation for short pollution events[J]. Water Research, 2019, 160:350-360
Tran H N, You S J, Hosseini-Bandegharaei A, et al. Mistakes and inconsistencies regarding adsorption of contaminants from aqueous solutions:A critical review[J]. Water Research, 2017, 120:88-116
Booij K, Robinson C D, Burgess R M, et al. Passive sampling in regulatory chemical monitoring of nonpolar organic compounds in the aquatic environment[J]. Environmental Science & Technology, 2016, 50(1):3-17
Harman C, Allan I J, Vermeirssen E L M. Calibration and use of the polar organic chemical integrative sampler-a critical review[J]. Environmental Toxicology and Chemistry, 2012, 31(12):2724-2738
Huckins J N, Petty J D, Lebo J A, et al. Development of the permeability/performance reference compound approach for in situ calibration of semipermeable membrane devices[J]. Environmental Science & Technology, 2002, 36(1):85-91
Mazzella N, Lissalde S, Moreira S, et al. Evaluation of the use of performance reference compounds in an Oasis-HLB adsorbent based passive sampler for improving water concentration estimates of polar herbicides in freshwater[J]. Environmental Science & Technology, 2010, 44(5):1713-1719
Taylor A C, Fones G R, Vrana B, et al. Applications for passive sampling of hydrophobic organic contaminants in water-a review[J]. Critical Reviews in Analytical Chemistry, 2021, 51(1):20-54
Jeong Y, Schäffer A, Smith K. A comparison of equilibrium and kinetic passive sampling for the monitoring of aquatic organic contaminants in German Rivers[J]. Water Research, 2018, 145:248-258
O'Brien D, Lewis S, Davis A, et al. Spatial and temporal variability in pesticide exposure downstream of a heavily irrigated cropping area:Application of different monitoring techniques[J]. Journal of Agricultural and Food Chemistry, 2016, 64(20):3975-3989
McKay S, Tscharke B, Hawker D, et al. Calibration and validation of a microporous polyethylene passive sampler for quantitative estimation of illicit drug and pharmaceutical and personal care product (PPCP) concentrations in wastewater influent[J]. Science of the Total Environment, 2020, 704:135891
Kaserzon S L, Hawker D W, Booij K, et al. Passive sampling of perfluorinated chemicals in water:In-situ calibration[J]. Environmental Pollution, 2014, 186:98-103
Llorca J, Gutiérrez C, Capilla E, et al. Constantly stirred sorbent and continuous flow integrative sampler:New integrative samplers for the time weighted average water monitoring[J]. Journal of Chromatography A, 2009, 1216(31):5783-5792
Vrana B, Mills G A, Kotterman M, et al. Modelling and field application of the Chemcatcher passive sampler calibration data for the monitoring of hydrophobic organic pollutants in water[J]. Environmental Pollution, 2007, 145(3):895-904
Katritzky A R, Lobanov V S, Karelson M. QSPR:The correlation and quantitative prediction of chemical and physical properties from structure[J]. Chemical Society Reviews, 1995, 24(4):279-287
Hu J W, Zhang X Y, Wang Z W. A review on progress in QSPR studies for surfactants[J]. International Journal of Molecular Sciences, 2010, 11(3):1020-1047
Miller T H, Baz-Lomba J A, Harman C, et al. The first attempt at non-linear in silico prediction of sampling rates for polar organic chemical integrative samplers (POCIS)[J]. Environmental Science & Technology, 2016, 50(15):7973-7981
Miège C, Mazzella N, Allan I, et al. Position paper on passive sampling techniques for the monitoring of contaminants in the aquatic environment-Achievements to date and perspectives[J]. Trends in Environmental Analytical Chemistry, 2015, 8:20-26
Poulier G, Lissalde S, Charriau A, et al. Can POCIS be used in Water Framework Directive (2000/60/EC) monitoring networks? A study focusing on pesticides in a French agricultural watershed[J]. The Science of the Total Environment, 2014, 497-498:282-292
Tang J F, Chen S, Xu Y P, et al. Calibration and field performance of triolein embedded acetate membranes for passive sampling persistent organic pollutants in water[J]. Environmental Pollution, 2012, 164:158-163
Bishop N, Jones-Lepp T, Margetts M, et al. Wastewater-based epidemiology pilot study to examine drug use in the Western United States[J]. The Science of the Total Environment, 2020, 745:140697
Poulier G, Lissalde S, Charriau A, et al. Estimates of pesticide concentrations and fluxes in two rivers of an extensive French multi-agricultural watershed:Application of the passive sampling strategy[J]. Environmental Science and Pollution Research, 2015, 22(11):8044-8057
Monteyne E, Roose P, Janssen C R. Application of a silicone rubber passive sampling technique for monitoring PAHs and PCBs at three Belgian coastal harbours[J]. Chemosphere, 2013, 91(3):390-398
Gao X Z, Huang P, Huang Q H, et al. Organophosphorus flame retardants and persistent, bioaccumulative, and toxic contaminants in Arctic seawaters:On-board passive sampling coupled with target and non-target analysis[J]. Environmental Pollution, 2019, 253:1-10
Gao X Z, Xu Y P, Ma M, et al. Distribution, sources and transport of organophosphorus flame retardants in the water and sediment of Ny-Ålesund, Svalbard, the Arctic[J]. Environmental Pollution, 2020, 264:114792
Allan I J, Booij K, Paschke A, et al. Field performance of seven passive sampling devices for monitoring of hydrophobic substances[J]. Environmental Science & Technology, 2009, 43(14):5383-5390
Friedman C L, Burgess R M, Perron M M, et al. Comparing polychaete and polyethylene uptake to assess sediment resuspension effects on PCB bioavailability[J]. Environmental Science & Technology, 2009, 43(8):2865-2870
Liscio C, Magi E, Di Carro M, et al. Combining passive samplers and biomonitors to evaluate endocrine disrupting compounds in a wastewater treatment plant by LC/MS/MS and bioassay analyses[J]. Environmental Pollution, 2009, 157(10):2716-2721
Williams R J, Johnson A C, Smith J J, et al. Steroid estrogens profiles along river stretches arising from sewage treatment works discharges[J]. Environmental Science & Technology, 2003, 37(9):1744-1750
Mitchell C, Brodie J, White I. Sediments, nutrients and pesticide residues in event flow conditions in streams of the Mackay Whitsunday Region, Australia[J]. Marine Pollution Bulletin, 2005, 51(1-4):23-36
Rabiet M, Margoum C, Gouy V, et al. Assessing pesticide concentrations and fluxes in the stream of a small vineyard catchment-Effect of sampling frequency[J]. Environmental Pollution, 2010, 158(3):737-748
Baz-Lomba J A, Harman C, Reid M, et al. Passive sampling of wastewater as a tool for the long-term monitoring of community exposure:Illicit and prescription drug trends as a proof of concept[J]. Water Research, 2017, 121:221-230
Allan I J, Vrana B, Greenwood R, et al. A "toolbox" for biological and chemical monitoring requirements for the European Union's Water Framework Directive[J]. Talanta, 2006, 69(2):302-322
Ort C, Lawrence M G, Reungoat J, et al. Sampling for PPCPs in wastewater systems:Comparison of different sampling modes and optimization strategies[J]. Environmental Science & Technology, 2010, 44(16):6289-6296
Carlson J C, Challis J K, Hanson M L, et al. Stability of pharmaceuticals and other polar organic compounds stored on polar organic chemical integrative samplers and solid-phase extraction cartridges[J]. Environmental Toxicology and Chemistry, 2013, 32(2):337-344
Rantalainen A L, Cretney W J, Ikonomou M G. Uptake rates of semipermeable membrane devices (SPMDs) for PCDDs, PCDFs and PCBs in water and sediment[J]. Chemosphere, 2000, 40(2):147-158
Li H X, Helm P A, Metcalfe C D. Sampling in the Great Lakes for pharmaceuticals, personal care products, and endocrine-disrupting substances using the passive polar organic chemical integrative sampler[J]. Environmental Toxicology and Chemistry, 2010, 29(4):751-762
Vrana B, Schüürmann G. Calibrating the uptake kinetics of semipermeable membrane devices in water:Impact of hydrodynamics[J]. Environmental Science & Technology, 2002, 36(2):290-296
Li H X, Vermeirssen E L, Helm P A, et al. Controlled field evaluation of water flow rate effects on sampling polar organic compounds using polar organic chemical integrative samplers[J]. Environmental Toxicology and Chemistry, 2010, 29(11):2461-2469
Novic A J, O'Brien D S, Kaserzon S L, et al. Monitoring herbicide concentrations and loads during a flood event:A comparison of grab sampling with passive sampling[J]. Environmental Science & Technology, 2017, 51(7):3880-3891
Gong X Y, Li K, Wu C L, et al. Passive sampling for monitoring polar organic pollutants in water by three typical samplers[J]. Trends in Environmental Analytical Chemistry, 2018, 17:23-33
Charlestra L, Amirbahman A, Courtemanch D L, et al. Estimating pesticide sampling rates by the polar organic chemical integrative sampler (POCIS) in the presence of natural organic matter and varying hydrodynamic conditions[J]. Environmental Pollution, 2012, 169:98-104
Bernal-González M, Durán-Domínguez-de-Bazúa C. Development of a passive sampler for monitoring of carbamate and s-triazine pesticides in surface waters[J]. Water, Air, & Soil Pollution, 2012, 223(8):5071-5085
Sobotka J, Lammel G, Slobodník J, et al. Dynamic passive sampling of hydrophobic organic compounds in surface seawater along the South Atlantic Ocean east-to-west transect and across the Black Sea[J]. Marine Pollution Bulletin, 2021, 168:112375
Moeris S, Vanryckeghem F, Demeestere K, et al. A margin of safety approach for the assessment of environmentally realistic chemical mixtures in the marine environment based on combined passive sampling and ecotoxicity testing[J]. The Science of the Total Environment, 2021, 765:142748
Vincent-Hubert F, Wacrenier C, Morga B, et al. Passive samplers, a powerful tool to detect viruses and bacteria in marine coastal areas[J]. Frontiers in Microbiology, 2021, 12:631174
Schreiner V C, Bakanov N, Kattwinkel M, et al. Sampling rates for passive samplers exposed to a field-relevant peak of 42 organic pesticides[J]. The Science of the Total Environment, 2020, 740:140376
Hawker D W. Modeling the response of passive samplers to varying ambient fluid concentrations of organic contaminants[J]. Environmental Toxicology and Chemistry, 2010, 29(3):591-596
Mutzner L, Vermeirssen E L M, Ort C. Passive samplers in sewers and rivers with highly fluctuating micropollutant concentrations-Better than we thought[J]. Journal of Hazardous Materials, 2019, 361:312-320
Shaw M, Mueller J F. Time integrative passive sampling:How well do chemcatchers integrate fluctuating pollutant concentrations?[J]. Environmental Science & Technology, 2009, 43(5):1443-1448
Jones L, Ronan J, McHugh B, et al. Emerging priority substances in the aquatic environment:A role for passive sampling in supporting WFD monitoring and compliance[J]. Analytical Methods, 2015, 7(19):7976-7984
Morin N, Miège C, Coquery M, et al. Chemical calibration, performance, validation and applications of the polar organic chemical integrative sampler (POCIS) in aquatic environments[J]. TrAC Trends in Analytical Chemistry, 2012, 36:144-175
Endo S, Matsuura Y. Characterizing sorption and permeation properties of membrane filters used for aquatic integrative passive samplers[J]. Environmental Science & Technology, 2018, 52(4):2118-2125
Endo S, Matsuura Y, Vermeirssen E L M. Mechanistic model describing the uptake of chemicals by aquatic integrative samplers:Comparison to data and implications for improved sampler configurations[J]. Environmental Science & Technology, 2019, 53(3):1482-1489
Bernard M, Boutry S, Tapie N, et al. Lab-scale investigation of the ability of polar organic chemical integrative sampler to catch short pesticide contamination peaks[J]. Environmental Science and Pollution Research International, 2022, 29(1):40-50
DiFilippo E L, Eganhouse R P. Assessment of PDMS-water partition coefficients:Implications for passive environmental sampling of hydrophobic organic compounds[J]. Environmental Science & Technology, 2010, 44(18):6917-6925
Jahnke A, Mayer P, Adolfsson-Erici M, et al. Equilibrium sampling of environmental pollutants in fish:Comparison with lipid-normalized concentrations and homogenization effects on chemical activity[J]. Environmental Toxicology and Chemistry, 2011, 30(7):1515-1521
Vallejo A, Prieto A, Moeder M, et al. Calibration and field test of the polar organic chemical integrative samplers for the determination of 15 endocrine disrupting compounds in wastewater and river water with special focus on performance reference compounds (PRC)[J]. Water Research, 2013, 47(8):2851-2862
Beckers L M, Brack W, Dann J P, et al. Unraveling longitudinal pollution patterns of organic micropollutants in a river by non-target screening and cluster analysis[J]. The Science of the Total Environment, 2020, 727:138388
Hahn R Z, Augusto do Nascimento C, Linden R. Evaluation of illicit drug consumption by wastewater analysis using polar organic chemical integrative sampler as a monitoring tool[J]. Frontiers in Chemistry, 2021, 9:596875